MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

Start here: choose a route

Target: use matched fresh trials to compare thermal protectors, change a design, and revise a claim. Intended for Grade 6; relevant standards are in the Grades 6–8 band.

Practical route

Work under teacher supervision. Read the design brief through instruments and trial order. Record your phase’s instrument checks at instrument-check record. Run three first comparisons using the first-comparison trial 1–3 record forms. Compare results at compare the first trials. Read commit to a redesign and run three retests using the retest trial 1–3 record forms; finish the Reassess the Redesign and Evidence and Explanation tasks.

Supplied-data route

No equipment is needed. Read the brief and procedure, then use supplied first-comparison record and supplied redesign/retest record, which are fictional constructed records. Complete compare the first trials, commit to a redesign, reassess the redesign, evidence and explanation and a fresh later check. These records are not measurements from this class.

Ways to respond

Write, dictate, explain orally to a recorder, or use a labeled sketch/table. Give the same quantities, comparison conditions and evidence in any format. Graph drawing is optional.

Water is not for drinking. Keep cups in spill trays. Do not heat, cut, puncture or modify equipment. Tell the teacher about spills, leaks, damaged equipment or an unstable cup.

Page 1 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

the design brief

Design a removable dry sleeve that may slow the warming of 150 mL of cool water in a covered plastic cup for 10 minutes in a classroom. This is a classroom comparison; it makes no promise about refrigeration, food, medicines or a particular final temperature.

The original sleeve uses one supplied 26 cm × 6 cm felt sheet, at most 3 mm thick. Baseline bare cup has no sleeve. The redesigned sleeve may use at most two supplied sheets total and at most 30 cm of tape. Its footprint must fit within a 12 cm diameter circle; its height must be at most 9 cm. Do not cover the base, top cover, probe slot or display.

Performance aim: look for less warming than the identified reference in comparable trials. A small or inconsistent difference can leave the result inconclusive. There is no numeric thermal pass mark.

1.Name the performance aim and three resource/size constraints. What result would leave the thermal claim inconclusive?

2.Predict how original sleeve might compare with bare cup. Explain why water might still warm in either cup.

Page 2 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

assemble and label

Teacher supplies three identical stable rigid plastic cups: a bare reference cup, a cup for the original sleeve and a cup for the redesigned sleeve. Nominal capacity 250–300 mL; approximately straight sides, 7.5 cm internal diameter, 8 cm tall and a broad flat base at least 6 cm across. Each has an identical loose-fitting plastic cover with a factory-made opening/slot for a supported probe. Covers are not sealed or pressurized. The teacher checks that the probes fit without cutting.

Put bare cup and original sleeve in separate marked positions in one dry spill tray, about 15 cm apart, away from sunlight, vents and electrical equipment. Keep them there during a run.

Wrap one dry 26 × 6 cm sheet around the cup used for the original sleeve. Center it vertically: approximately 1 cm of wall remains bare above and below. Overlap the seam; use two pre-cut 5 cm tape strips to hold the sleeve. Keep the reference cup bare. Leave both cup bases directly on the same tray surface.

Fit identical covers. Support probes vertically through the existing slots using the teacher-supplied holder. The sensing region must be fully immersed, centered horizontally, with its tip 1.5 cm above the inner base, not touching any wall or base. Mark/check insertion depth with the teacher.

Text equivalent of the setup: left and right cup on one level tray; equal water depth; identical covers and centered probes; bare cup; original sleeve around side wall only. Probe displays remain dry and readable.

1.Draw or describe the assembled pair. Label the sleeve, exposed base/top, water, cover and probe location. Explain one condition that must match.

Page 3 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

run a matched pair

Use two suitable non-glass liquid probes with 0.1 °C displays, checked by the teacher for water immersion, temperature range and response instructions. Display steps do not establish accuracy. A separate classroom instrument records room air at cup height.

Standard conditions: room air 20–24 °C; common gently mixed cool-water batch 12–14 °C. Measure 150 mL into each cup using the same marked measure, within 2 mL. No ice goes into cups. Record the actual conditions.

Put probes at the marked depth and covers in place. Wait for the teacher-checked response interval (at least 60 seconds). Read both. Starts must differ by no more than 0.5 °C, both be 12–14 °C, and room must be at least 6 °C warmer. If not, keep the readings, mark a failed start, and ask for a fresh matched pair.

When both starts qualify, record both 0-minute readings and the actual clock time; start the timer. Record both probes at 5 and 10 minutes, within 15 seconds of each other and the target time. Record actual time if late. Keep probes in place; do not stir, move cups, lift covers or handle sleeves during a run.

Record room air at 0 and 10 minutes, missing readings, spills, movement and wet sleeves. A room shift over 1 °C, a missing 0/10 reading or a changed procedure flags an inconclusive comparison; retain it and repeat with fresh water if time permits.

After each run, retain the reading sheet. Teacher drains cups, checks sleeve dryness, and conditions cup interiors with 150 mL room-temperature water for 5 minutes. Drain and dry interiors before fresh cool water. Keep sleeves assembled and dry between runs; log any rebuild. Three timepoints are ONE trial. Three trials require three fresh water pairs.

Page 4 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

instruments and trial order

Before each phase, the teacher places probes A and B together in stirred common water, first at room-water temperature and then at cool-batch temperature. Hold equal immersion depths without contact. Wait the maker’s response interval and at least 60 seconds; then read twice 30 seconds apart. Each probe must change no more than 0.2 °C between these readings and their displayed readings must differ no more than 0.5 °C. If not met within 2 minutes after the minimum response interval, replace/check equipment or use supplied data. Record all readings.

This is a consistency/response check, not calibration or proof of accuracy. Do not silently correct readings by subtracting an assumed offset. Repeat the check after the phase; a new disagreement flags possible drift.

First comparison order: F1: bare cup left/A, original sleeve right/B. F2: bare cup right/B, original sleeve left/A. F3: bare cup left/A, original sleeve right/B. Labels follow cups, not position. Teacher moves empty cups and swaps probes between trials, never during a run. This reduces a one-position or one-probe explanation but three trials do not perfectly balance everything.

1.A reads 13.0 °C and B reads 13.7 °C in the same mixed water after settling. Should the pair start? What does a 0.1 °C display tell you?

2.Why swap positions/probes between fresh trials? Why are 0, 5 and 10 minutes not three independent trials?

Page 5 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

instrument-check record

BLANK empirical form. Use one copy for each group/phase, or attach a clearly identified teacher-recorded check for your exact probes. Follow the instrument-check directions on the Instruments and Trial Order page. Keep before and after values. This checks consistency and response, not calibration.

1.Record group/date/phase and check-record ID; probe A/B maker/model/IDs; teacher-checked immersion/response instructions and required wait; classroom air instrument ID/location. Record any supplied maker accuracy information as stated, or “not available”; do not infer it from display resolution.

BLANK empirical form; °C readings, wait in seconds; second read 30 s after first.

Blank empirical instrument-check record; no readings supplied.

Check waterA read1 °CB read1 °CA read2 °CB read2 °CWait s
Before: room________________________________________
Before: cool________________________________________
After: room________________________________________
After: cool________________________________________

Record actual check timestamps, conditions, replacement instrument IDs and action here or on an attached named note. Link every run to its check ID. If instruments are replaced mid-phase, use a new check record and fresh samples.

Page 6 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

commit to a redesign

Retest redesigned sleeve AGAINST original sleeve, the original one-sheet dry felt prototype, not against bare cup and not against an old reading. Keep original sleeve assembled and dry. Build redesigned sleeve on the third identical cup. redesigned sleeve may have one or two supplied sheets; total ≤30 cm tape, footprint ≤12 cm diameter, height ≤9 cm. Keep base/top/slot exposed. Teacher checks stability and probe placement.

Use the fresh-pair method and consistency check on the Instruments and Trial Order page. R1: original sleeve left/A, redesigned sleeve right/B; R2: original sleeve right/B, redesigned sleeve left/A; R3: original sleeve left/A, redesigned sleeve right/B. Preserve original sleeve as the concurrent reference. Keep redesigned sleeve assembled between runs; log any change.

1.Before seeing retest results, specify redesigned sleeve’s materials, dimensions and tape total. State your prediction, named reference and controls. If using supplied data, propose a design first; the later record is for the specified fictional redesigned sleeve, not your proposal.

2.Why is comparing today’s redesigned sleeve only with yesterday’s original sleeve endpoint weaker than concurrent retesting?

Page 7 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

fresh paired trial 1

Blank empirical record. Run R1; reference: original one-sheet sleeve; prototype: declared redesigned sleeve. Use the fresh-pair procedure and instrument-check directions on the Instruments and Trial Order page. Record °C exactly as displayed; never invent a missing reading.

1.Record group/date; cup and sensor IDs/left-right positions; cover and sleeve condition; measured mL each; common-batch temperature; probe response interval; linked instrument-check record ID (instrument-check record).

BLANK empirical record; minutes and °C, actual timestamps required.

Blank empirical recording form: no readings supplied.

Target minActual clockReference °CPrototype °CRoom °CNotes
0________________________________________
5________________________—________
10________________________________________

2.Record changes, late/missing readings, wet materials, spills or movement, even if the result looks surprising. Mark usable, flagged or failed start; give a reason. Record any fresh replacement run with a new ID.

Page 8 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

fresh paired trial 2

Blank empirical record. Run R2; reference: original one-sheet sleeve; prototype: declared redesigned sleeve. Use the fresh-pair procedure and instrument-check directions on the Instruments and Trial Order page. Record °C exactly as displayed; never invent a missing reading.

1.Record group/date; cup and sensor IDs/left-right positions; cover and sleeve condition; measured mL each; common-batch temperature; probe response interval; linked instrument-check record ID (instrument-check record).

BLANK empirical record; minutes and °C, actual timestamps required.

Blank empirical recording form: no readings supplied.

Target minActual clockReference °CPrototype °CRoom °CNotes
0________________________________________
5________________________—________
10________________________________________

2.Record changes, late/missing readings, wet materials, spills or movement, even if the result looks surprising. Mark usable, flagged or failed start; give a reason. Record any fresh replacement run with a new ID.

Page 9 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

fresh paired trial 3

Blank empirical record. Run R3; reference: original one-sheet sleeve; prototype: declared redesigned sleeve. Use the fresh-pair procedure and instrument-check directions on the Instruments and Trial Order page. Record °C exactly as displayed; never invent a missing reading.

1.Record group/date; cup and sensor IDs/left-right positions; cover and sleeve condition; measured mL each; common-batch temperature; probe response interval; linked instrument-check record ID (instrument-check record).

BLANK empirical record; minutes and °C, actual timestamps required.

Blank empirical recording form: no readings supplied.

Target minActual clockReference °CPrototype °CRoom °CNotes
0________________________________________
5________________________—________
10________________________________________

2.Record changes, late/missing readings, wet materials, spills or movement, even if the result looks surprising. Mark usable, flagged or failed start; give a reason. Record any fresh replacement run with a new ID.

Page 10 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

supplied redesign/retest record

CONSTRUCTED FICTIONAL RECORDS. These belong to the specified fictional redesigned sleeve, not to a learner’s unbuilt redesign.

Fictional redesigned sleeve: two 26 × 6 cm felt sheets, each 2 mm thick, 20 cm tape, footprint 9 cm diameter, height 8 cm; base/top/slot exposed. original sleeve reference: original single-sheet sleeve, unchanged. 150 mL each; identical cups/covers/probe placement; 60 s minimum response; fresh water and room-water reset each run. Day 2.

R1 original sleeve left/A, redesigned sleeve right/B; R2 original sleeve right/B, redesigned sleeve left/A; R3 original sleeve left/A, redesigned sleeve right/B. Fictional room/cool consistency readings before/after: same as Day 1. R2: a spill wet redesigned sleeve’s outer sleeve near 2 min; retained, flagged. Teacher replaced it with identical dry material for R3, recorded rebuild; R3 is not an unchanged uninterrupted sequence.

constructed R1; reference original sleeve, prototype redesigned sleeve; dry.

Constructed teaching data: these values were invented for this activity, not collected in an experiment. Not computationally simulated.

MinuteClockReference °CPrototype °CRoom °C
010:0013.013.122.0
510:0514.214.1—
1010:1015.315.022.1
constructed R2; WET-SLEEVE FLAG; retained.

Constructed teaching data: these values were invented for this activity, not collected in an experiment. Not computationally simulated.

MinuteClockReference °CPrototype °CRoom °C
010:2013.013.022.1
510:2514.314.5—
1010:3015.415.722.2
constructed R3; rebuilt dry redesigned sleeve; change logged.

Constructed teaching data: these values were invented for this activity, not collected in an experiment. Not computationally simulated.

MinuteClockReference °CPrototype °CRoom °C
010:4013.113.022.2
510:4514.314.1—
1010:5015.415.022.2
Page 11 of 12
MENTOR TEACHING · THERMAL ENERGY | Classroom copy · 1 October 2026

reassess the redesign

Use your R1–R3 records or supplied redesign/retest record. Keep the wet/changed/missing records visible. Compare redesigned sleeve with concurrent original sleeve, using the rises for each pair.

1.List each reference rise, redesign rise, difference and flag. Does the evidence support improvement? What should happen to an awkward result?

2.Check the redesign’s resource constraints. Write a revised claim and one exact next comparison.

Page 12 of 12